basic introduction

ZRLK's professional testing team can provide you with multi-faceted paint testing services, help you to avoid the loss caused by the wrong material selection, and provide clear directions and suggestions for material improvement. At the same time, it can also be used to monitor the quality of factory production.

Service background

The material coated on the surface of the object can bond well with the base material and form a complete and tough protective film, which we call the paint. In fact, paint and paint are the same concept, and paint is a long-used customary name. After the introduction of our country, we will use it as an industry term. At present, the entire architectural coatings market continues to grow and the entire industry is undergoing continuous upgrades. It has become a trend to produce high-value-added products with better quality and stricter environmental protection standards. Environmental protection and health are the biggest concerns of coatings. point.

ZRLK's professional testing team can provide you with multi-faceted paint testing services, help you to avoid the loss caused by the wrong material selection, and provide clear directions and suggestions for material improvement. At the same time, it can also be used to monitor the quality of factory production.

Service Content

Test items

Harmful substance content, low temperature flexibility, water impermeability, tensile test, low temperature flexure, heating expansion rate, surface drying time, solid drying time, solid content

standard test

GB 23445-2009, GB 16777-2008, JC/T 864-2008, JC/T 2090-2011, GB 18581, GB 18582

Applicable Products

Building materials, coatings

Test content

Harmful substance content

1. Test principle: determine the content of volatile organic compounds, benzene, toluene, ethylbenzene, xylene, TDI, HDI, methanol, halogenated hydrocarbons, heavy metals and other harmful substances in paint or coated products.

2. Test standard: GB 18581, GB 18582, GB 23445-2009 (Section 5)

Low temperature flexibility

1. Test principle: The sample is bent after a low temperature treatment for a period of time, and whether the sample is broken from a certain angle.

2. Test standard: GB 16777-2008 (Section 13.2), C/T 864-2008 (Section 5.4.4)

Impermeable

1. Test principle: put the sample in a specific device and apply a specific pressure at a certain time to see if the sample leaks.

2. Test standards: GB 23445-2009 (Section 6.2), GB 16777-2008 (Section 15), JC/T 864-2008 (Section 5.4.5), JC/T 2090-2011 (Section 7.6)

Low temperature bendability

1. Test principle: After a period of treatment, the sample is bent 90 degrees at a specific temperature to watch the appearance of the sample.

2. Test standards: GB 23445-2009 (Section 6.2), GB 16777-2008 (Section 14.2), JC/T 2090-2011 (Section 7.7.2)

Tensile test

1. Test principle: Tensile the specimen until it breaks, and measure its tensile strength.

2. Test standards: GB 23445-2009 (Section 6.2), GB 16777-2008 (Section 9.2), JC/T 864-2008 (Section 5.4.3)

Heating expansion rate

1. Test principle: heat the sample and measure the rate of change of dimensions before and after heating.

2. Test standard: GB 16777-2008 (Section 12), JC/T 864-2008 (Section 5.5.8)

Dry time

1. Test principle: apply the coating to the aluminum plate, and record the time when the coating is not adhered with the finger.

2. Test standards: GB 16777-2008 (Section 16.2.1), JC/T 864-2008 (Section 5.7.1), JC/T 2090-2011 (Section 7.4)

Working time

1. Test principle: apply the coating to the aluminum plate, and record the time when the coating is cut with a knife, and there is no finger sticking in the bottom layer and the film.

2. Test standards: GB 16777-2008 (Section 16.2.2), JC/T 864-2008 (Section 5.7.2), JC/T 2090-2011 (Section 7.4)

Solid content

1. Test principle: After heating the material, certain substances will be volatilized, and the rest is solid content.

2. Test standard: GB 23445-2009 (Section 6.2), GB 16777-2008 (Section 5), JC/T 864-2008 (Section 5.4.6)

Our advantage

1. With a professional qualification and experienced expert technical team, we can provide you with professional consultation and services.

2. Have advanced laboratory equipment to ensure the accuracy and reliability of test data.

3. As a third-party testing and certification organization trusted by customers worldwide, we are your certificate of quality.


Online consultation

Online consultation

Recommend
  • COC certification in Algeria

    COC certification in Algeria

    COC certification in Algeria is a mandatory certification for products exported to Algeria, ensuring that the products comply with the country\'s safety, quality, and technical standards. The certification process includes document review, product testing, and factory inspection. Products that pass certification can be legally sold in the local market, protecting consumer interests and promoting fair trade.

  • Saudi Arabia GCC Certification

    Saudi Arabia GCC Certification

    GCC certification is the abbreviation for Gulf Cooperation Council certification, which is a mandatory certification requirement for products entering the market in Saudi Arabia and other countries in the Gulf region.

  • Moroccan COC certification

    Moroccan COC certification

    The Moroccan government implements strict supervision on imported electronic devices, and COC certification is a mandatory requirement to ensure that products comply with local safety, quality, and environmental standards.

Paint testing

ZRLK\'s professional testing team can provide you with multi-faceted paint testing services, help you to avoid the loss caused by the wrong material selection, and provide clear directions and suggestions for material improvement. At the same time, it can also be used to monitor the quality of factory production.

Get a quote